Description
The BK-410 Automatic Chemistry Analyzer is a cutting-edge diagnostic instrument designed to meet the rigorous demands of high-throughput clinical laboratories. Delivering up to 400 tests per hour, this system ensures fast, precise, and efficient biochemical analysis with minimal downtime.
Key Features
-
49 Sample Positions
-
56 Reagent Positions
-
120 Reusable Reaction Cuvettes
-
Throughput: 400 Tests/Hour
-
Advanced Probe with Anti-Collision & Liquid Level Detection
-
Continuous 24-Hour Operation
-
Built-in Reagent Cooling (2–12℃)
-
Automatic Probe and Cuvette Washing
Technical Specifications
Model
-
BK-410
Performance
-
Test Capacity: 400 Tests/Hour (ISE Optional)
-
Analysis Modes: End-point, Fixed-time, Rate (Kinetic), Turbidimetry
-
Certifications: CE, FDA, ISO9001, ISO14001, ISO13485
-
System Configuration: Open or closed system options; supports 24/7 continuous operation
Sample & Reagent System
-
Sample Positions: 49
-
Reagent Positions: 56
-
Sample Volume: 2–70μL
-
Reagent Volume: 20–350μL
-
Probe: Equipped with anti-collision and liquid level detection
-
Probe Cleaning: Fully automatic internal and external washing
-
Reagent Cooling: Maintains temperature at 2–12℃ for up to 24 hours
Reaction System
-
Temperature Control: Water bath system at 37±0.2℃ with real-time monitoring
-
Cuvettes: 120 reusable
-
Mixing Mechanism: Independent stirring with automatic frequency adjustment
-
Cuvette Washing: Automated cleaning after each reaction
Optical System
-
Light Source: Halogen lamp with water cooling
-
Spectrophotometry: Post-spectral analysis
-
Wavelength Range: 340–800nm, precision <±1nm
-
Absorbance Range: 0–3.0 Abs
Calibration & Quality Control
-
Calibration Methods:
-
Linear: K factor, 1-point, 2-point, multi-point
-
Non-linear: Spline, Polygon, Index, Logarithm, Logit-4P, Logit-5P
-
-
Quality Control Tools: Real-time QC, Westgard multi-rule, Cumulative Sum Check, Twin Plot (2D)
Data & Connectivity
-
Software: Compatible with Windows 7/8/10 (32 or 64-bit)
-
LIS Connectivity: Bi-directional with HL7 protocol support
-
Interface: LAN port access
-
Printer: External, supports multiple report formats
Working Conditions
-
Power Supply:
-
Standard: AC220V±10%, 50/60Hz
-
Optional: 110V±10%, 60Hz
-
-
Power Consumption: 650VA
-
Temperature Range: 15–30℃ (±2℃)
-
Water Consumption: <10L/h (Deionized water)
-
Humidity Range: 40–85%
Dimensions & Weight
-
External Dimensions (W×D×H): 973 × 645 × 520 mm
-
Net Weight: 96 kg
-
Package Dimensions (W×D×H): 1130 × 735 × 1040 mm
-
Gross Weight: 141 kg

Reviews
There are no reviews yet.